Page 76 - JSOM Fall 2025
P. 76

FIGURE 1 Search flow diagram.


                     Studies from databases/registers (n=22)         References from other sources (n=0)
                      Embase (n=5)                                    Citation searching (n=0)
                      PubMed (n=13)                                   Grey literature (n=0)
                      Google Scholar (n=4)
                Identification                                       References removed (n=0)




                                                                      Duplicates identified manually (n=0)
                                                                      Duplicates identified by Covidence (n=0)
                                                                      Marked as ineligible by automation tools (n=0)
                                                                      Other reasons (n=0)





                     Studies Studies screened (n=22)                Studies excluded (n=2)
                                                                     Non-English article (n=1)
                                                                     Wrong study design (n=1)


                 Screening  Studies sought for retrieval (n=20)             Studies not retrieved (n=0)




                       Studies assessed for eligibility (n=20)      Studies excluded (n=4)
                                                                     Not full text (n=1)
                                                                     Wrong study design (n=3)





                 Included  Studies included in review (n = 16)






          with varying power consumptions. The water bath achieved   Electric Tea Kettle
          by a slow cooker is not temperature-controlled, as the water   The electric tea kettle is an alternative way to achieve a tem-
          temperature  will  increase  to  the  selected  heat  setting. These   perature-appropriate water bath. Electric tea kettles have a va-
          temperature selectors are not industry-standard and may vary   riety of shapes, sizes, and weights. A typical electric tea kettle
          between manufacturers.                             can weigh between 0.45 and 1.1kg and can heat 1.7L of water
                                                             up to 100°C.  Silicone-based, collapsible tea kettles provide a
                                                                       8
          To date, only one study has evaluated FFP thawing kinetics   smaller carrying profile when folded and weigh approximately
          with a slow cooker. The researchers used a 4.2L capacity slow   0.63kg; these collapsible kettles can hold 600mL. 9
          cooker and investigated FFP thaw times between groups using
          prewarmed water at W, L, H settings (preheated for 1 hour)   Only one published study has evaluated the efficacy of electric
          versus non-preheated water.  Two units of FFP were simul-  tea kettle heated water for thawing FFP. In this study, research-
                                6
          taneously submerged with each heat setting for both groups.   ers poured 100°C water into a porcelain basin, promptly added
          In the prewarmed water group, FFP thawed in 56.0 (SD 3.4)   two units of FFP, and measured thaw times.  This process was
                                                                                               6
          minutes via the low setting, 31.3 (SD 3.1) minutes via the me-  repeated four times to estimate mean thaw times. The research-
          dium setting, and 23.0 (SD 4.4) minutes via the high setting.    ers recorded the average thaw time as 23.0 (SD 4.4) minutes.
                                                                                                            6
                                                         6
          In the non-preheated water group, FFP thawed in 81.3 (SD   Coagulation assays revealed no statistically significant differ-
          7.2) minutes via the warm setting, 67.5 (SD 3.5) minutes via   ence in hemostatic properties between plasma thawed by a
          the low setting, and 62.5 (SD 3.6) minutes via the high set-  clinical thawer and those thawed by an electric kettle method. 6
          ting.  There was no statistical difference in the hemostatic ca-
              6
          pabilities of FFP thawed by a slow cooker versus FFP thawed   Sous Vide
          by a standard clinical plasma thawer. Notably, six units of   The sous vide is another culinary tool that uses a temperature-
          FFP thawed slowly enough on lower heat settings to develop   controlled circulating water bath to cook meats and vege-
          cryoprecipitate. 6                                 tables.  The device continuously heats and circulates water