Page 223 - 2023 SMOG Digital
P. 223

Ventilator Exchange Checklist
           Two person procedure- One for airway, one for ventilator.

             • All persons in the room/area in full PPE
             • All equipment gathered and field prepped
             • Transport ventilator preset / staged in sequence with circuit-
               EtCO 2- *Filter-Inline Suction
             • Temporarily hyper-oxygenate with 100% FiO 2 prior to
               exchange
             • Allow patient to inhale
             • Clamp tube at end of inhalation (ensure use of smooth
               clamps or pad ET tube)
             • Place primary/in use ventilator in Stand-by (ex. T1) or
               disconnect inspiratory limb from ventilator side- ensuring to
               minimize contamination from in-use vent and circuit
             • Break the circuit
             • Place transport ventilator on patient
             • Unclamp ET Tube (ensure tube is open)
             • Verify Ventilation



           * HME/viral filters should be placed as close to patient as possible
           and in accordance with manufacturer guidelines