FIGURE 1 Example of “disappearance” of white letter print on a red background under dimmed red light conditions. The upper third of
the vial’s medication label has a bright red background with white letters printed on it, stating the contained drug and drug concentration
(propofol 20mg/mL). The text is clearly visible in daylight and in white light mode of the head lamp (A) but disappears under red light
condition (B). Photo taken in the medical (passenger) compartment of our Airbus H-135 HAA helicopter at night, illuminated only with a
®
commercial head lamp (Black Diamond ).
(A) (B)
FIGURE 2 Example of complete “disappearance” of red letter print on a white background under dimmed red light conditions. The two
photographs show the same section of the medical (passenger) compartment of our Airbus H-135 HAA helicopter. (A) Taken in daylight.
®
(B) Taken in darkness, illuminated by a commercial head lamp (Black Diamond ) in red light mode.
(A) (B)
References 8. Dexter FC, Stearns EI. Example of metamerism; extreme example
1. Peters JH, et al. Helicopter emergency medical service patient of color change with varying illuminant. J Opt Soc Am. 1948;38
transport safe at night? Air Med J. 2014;33(6):296–298. (9):816.
2. Dery M, et al. Results and recommendations from the helicopter 9. Oulton DP, Taylor H. Inter-observer agreement on visual colour
EMS pilot safety survey 2005. Air Med J. 2007;26(1):38–44. matches and the role of metamerism as a cause of disagreement.
3. Salazar G, Temme L, Antonio JC. Civilian use of night vision gog- Surface Coatings Int Part B-Coatings Trans. 2002;85(2):105–109.
gles. Aviat Space Environ Med. 2003;74(1):79–84. 10. Edwards SJ. Throwing light on metamerism, quantifying the
4. Pedler M, et al. Red-green versus blue tactical light: a direct, objec- change in a color match caused by change of illuminant. Leon-
tive comparison. J Spec Oper Med. 2017;16(4):54–58. ardo. 1989;22(2):215–218.
5. Calvano CJ, et al. Tactical lighting in Special Operations medi- 11. Long DL, Fairchild MD. Modeling observer variability and meta-
cine: survey of current preferences. J Spec Oper Med. 2013;13(4): merism failurein electronic color display. J Imaging Sci Technol.
15–21. 2014;58(3).
6. Aydin A, Bilge S, Eryilmaz M. Safest light in a combat area while 12. Newson DW. Nautical chart standardization. Int Hydrographic
performing intravenous access in the dark. J R Army Med Corps. Rev. 1984;61(2):111–122.
2018;164(5):343–346.
7. Van Buren JP, et al. Optimizing tactical medical performance: the
effect of light hue on vision testing. J Spec Oper Med. 2018;18(2):
75–78.
Red Light Illumination in HAA | 23