Page 179 - 2026 SMOG
P. 179

Y-SITE AND SOLUTION COMPATIBILITY
                                     Purpose
         The following contains the compatibility information presented on the following two charts:
         •  Y-site Compatibility: A single drug that is administered simultaneously at a Y-site connection
           with another drug in a solution
         •  Solution Compatibility: A single drug in a solution
         Note: The resource utilized can provide additional information containing the specific studies
         noted in the Incompatible or Uncertain categories. It can also perform additional drug mixture
         compatibility (ex, admixture and syringe compatibility).
          Compatible   No change in visible or electronically determined particulates, haziness or
            “C”     turbidity, frank precipitation, color, or evolution of a gas.
                    All drug components in the test samples were found to be chemically stable
                    (<10% loss of intact drug) for at least 24 hours under the conditions being tested.
                    All drug components in the test samples were found to be chemically stable
                    (<10% loss of intact drug) for the entire period of the study under the conditions
                    being tested, even if the study period was <24 hours.
         Incompatible  A change in visible or electronically viewed (even if not visible) particulates;
            “N”     haziness or turbidity, frank precipitation, or color or gas evolution occurred
                    One or more drug components in the test samples exhibited a loss of intact drug
                    >10% within 24 hours under the conditions being tested.
          Uncertain   For research results that do not fit these conventional guidelines, the research
            “U”     results are designated as Uncertain or Variable. Apply judgment in using these
                    results. Examples include:
                    •  A transient precipitation formed upon mixing but then disappeared. The
                      precipitate may or may not show up again later.
                    •  Among repeat test samples, microparticulate formation was electronically
                      determined to have formed in some samples but not others.
                    •  The test drug in a solution was stable in one container type but not another or
                      with some drug delivery devices but not others.
                    •  Compatibility of a drug(s) is dependent on the manufacturer(s) of the products
                      and/or the use of specific product formulations.
                    •  When both compatible and incompatible study results are available for the
                      same drug pair. Many of these may be due to differences in concentrations of
                      either drug or in the solution diluent.
                    •  Any other research result that does not fit the conventional guidelines of
                      compatibility or incompatibility
           No data
            “NA”    No data for administration methods chosen
            N/A
             “/”    Not applicable
                           ™
                                 ™
                     ®
         Reference: UpToDate  Lexidrug  Trissel’s 2 IV Compatibility


                          2026 Standard Medical Operating Guidelines (SMOG)  •   171
   174   175   176   177   178   179   180   181   182   183   184