Truck model: Pack for 2–5 surgical patients with 80% of injury   House model: This model may allow for true surgical sets. The
              patterns. Includes increased quantities of all Ruck items.   number of sets required will depend on how many simultaneous
                             •  Litters                          OR tables the site is intended to provide. Consider frequency
              Added TCCC                                         and time required to resterilize instruments. Includes increased
              equipment      •  MASCAL kit                       quantities of all Truck items.
                             •  CBRNE kit                        Anesthetic     •  MAC catheters
                             •  Oxygen                           equipment
              Added anesthetic   •  OG tubes                     Medications    •  Increased IV fluids
              equipment
                             •  RIC catheters                    Surgical       •  Consider several of each instrument
              Added surgical   •  Consider two or more of each instrument set  instruments  set above
              instruments    •  Limited external fixator set                    •  Craniotomy set
                             •  Operating table/litter stands and               •  Several external fixator sets
              Other surgical    arm boards                                      •  Surgical suction and tubing
              equipment
                             •  Broselow bag                                    •  Surgical energy device (e.g., Bovie)
                             •  Point-of-care laboratory testing (iSTAT   Other surgical   •  Consider larger capacity blood refrigeration
                              requires regular maintenance including   equipment  equipment
                              calibration and cartridges must be                •  Litters
              Added electronics  temperature controlled)                        •  More than 1 OR table/litter stands ± arm
                             •  Battery-powered blood refridgerators             boards
                              and/or freezers
                                                                                •  Overhead free-standing lighting
                             •  Belmont Rapid Infuser
                                                                                •  Plasma thawer OR Belmont Rapid Infuser
                             •  Person-portable generator to power
                              electronics with maintenance kit                  •  Instrument sterilizer
              Added operational   •  Space heater                               •  More robust MASCAL kit
              equipment                                                         •  Additional litters
                             •  Fuel for generator
                             •  Tentage to set up patient care space   Electronics  •  Arterial catheter pressure-monitoring
                                                                                 equipment
              Abbreviations: CBRNE,  chemical, biological, radiological, nuclear,
              and explosive; MASCAL, mass casualty; RIC, rapid infusion catheter;   Operational   •  Larger generator(s) with required fuel,
              TCCC, Tactical Combat Casualty Care.               equipment       wiring, circuit panels
                                                                                •  Multiple space heaters
                                                                                •  Wall-mounted lighting
                                                                 Abbreviations: IV, intravenous; OR, operating room.