VASCULAR ACCESS VIA CENTRAL CATHETERS
                                 Clinical Indications
         •  In the presence of a life-threatening condition, with clear indications for immediate use of
           medication or fluid bolus. (Not for prophylactic IV access)
                                  Contraindications
         •  Suspected infection at the skin site
                                     Procedure
         •  Determine the type of catheter present: PICC, Broviac, Hickman, Groshong, Mediport, etc.
         Procedure for peripherally inserted central catheter (Cook, NeoPICC, etc.) and tunneled
         catheter (Broviac, Hickman, Groshong, etc.):
         •  Prepare equipment:
              ˚  2–3 10mL prefilled syringes of 0.9% NaCl
             Sterile gloves (if available)
              ˚
         •  If more than one lumen is available (PICCs, Hickmans, and Broviacs can have one, two, or
           three lumens), select the largest lumen available
         •  Vigorously cleanse the cap of the lumen with chlorhexidine or a 70% alcohol prep pad, and
           allow to dry
         •  Unclamp the selected catheter lumen and, using a prefilled 10mL syringe:
              ˚  Vigorously flush the catheter using a pulsating technique and maintaining pressure at the end
             of the flush to prevent reflux of fluid or blood
              ˚  If the catheter does not flush easily (note that a PICC line will generally flush more slowly
             and with greater resistance than a typical intravenous catheter), reclamp the selected lumen
             and attempt to use another lumen (if present)
              ˚  If unable to flush any of the lumens, the catheter cannot be used
         •  Attach the primed IV administration set and observe for the free flow of IV fluid
                        **Document procedure, results, and vital signs.**
            Procedure for Implanted Catheter (PortaCath, P.A.S. Port, or Medi-Port)
         •  Prepare all necessary equipment:
              ˚  Non-coring, right-angle needle specific for implanted vascular access ports
              ˚  2–3 prefilled 10mL syringes of 0.9% NaCl
              ˚  Sterile infusion port cap
              ˚  Sterile gloves (if available)
             Sterile occlusive dressing large enough to completely cover the insertion site
              ˚
         •  Identify the access site, usually located in the chest
         •  Vigorously cleanse the cap of the lumen with chlorhexidine or a 70% alcohol prep pad, and
           allow to dry
         •  Attach the infusion port cap to the end of the non-coring, right-angle needle tubing
         •  Prime the non-coring needle with attached tubing with saline using one of the prefilled 10mL
           syringes. Leave the syringe attached to the tubing
         •  Palpate the port to determine the size and center of the device
         •  Secure the access point port firmly between two fingers and firmly insert the non-coring needle
           into the port, entering at a direct 90° angle